How Many Times Is It Safe to Reset a Boiler Lockout?

Your boiler has locked out and you want to know whether pressing reset will fix it or make things worse.

A boiler lockout is the boiler's own safety switch. It has stopped firing because something is not right, and the reset button is there to clear a one-off interruption, not to override a fault. The safe rule is simple: reset once, and if the boiler locks out again, reset a second time only after you have made the checks below. If it keeps locking out, stop pressing reset and call a Gas Safe registered engineer1.

Pressing reset repeatedly does not fix anything. It clears the lockout each time, the boiler tries to fire, fails, and locks out again, and you learn nothing about the cause. The fault is still there, and on a gas appliance an unexplained fault is a reason to get a qualified person to look at it, not a reason to keep trying1.

Before you touch the button, work through the four checks that account for most lockouts an ordinary household can safely deal with: is there gas, is there power, is the pressure right, and has the condensate pipe frozen? If none of those explains it, the next step is an engineer, not another reset3.

Reset once or twice, then stop

A lockout is not a fault code in itself. It is the boiler telling you it tried to start and could not, so it shut itself down rather than keep trying. The reset clears that state and lets it attempt a start again. If the underlying cause has gone, the boiler fires and you are back to normal. If it has not, the boiler locks out again, and that repetition is the message1.

The method depends on your boiler. On a Baxi boiler with an ON/OFF/SELECTOR switch, the maker's instruction is to turn the selector switch to the R (Reset) position, hold it for at least 5 seconds and release6. Other makers use a dedicated reset button, and some use a sequence on the controls. Follow your own maker's instructions, which are usually printed inside the boiler casing or in the manual.

If the boiler locks out again after two resets, treat it as a fault that needs a Gas Safe registered engineer. Network operators are clear that a boiler fault unrelated to a power cut needs a Gas Safe registered engineer to come out and take a look1. You can find one through the Gas Safe Register website or by calling 0800 408 55001.

What the red light or fault code is telling you

A hand holding the reset control on a wall-mounted combi boiler
The reset control clears a lockout; it does not repair the fault behind it.

On a Baxi boiler, a lockout is identified by the red lockout light on or flashing6. That light is the boiler's way of saying it has shut down safely. It is not a diagnosis. The diagnosis comes from the fault code, if your boiler displays one, or from the pattern of when the lockout happens.

The pattern matters more than the code for an ordinary household. A lockout that happens once, on the coldest night of the year, and clears on the first reset points towards a frozen condensate pipe11. A lockout that follows a power cut points towards the interruption itself, and the boiler should recover on its own when electricity returns9. A lockout that repeats every few hours with no obvious trigger points towards a component fault, and that is an engineer's job1.

If your boiler shows a fault code, note it down before you reset, because the code may clear when the boiler restarts. Having the code ready when you call the engineer saves a visit. Our guide to boiler fault codes, flashing lights and lockouts explains what the common codes mean.

Checks to make before you press reset

Work through these four checks in order. Each one is something an ordinary household can safely look at, and together they cover the causes you can deal with yourself.

  1. Gas. Is the gas supply on? If there has been an outage and the supply has just been restored, make sure all the gas appliances in the property, including the boiler, cooker and gas fires, are turned off before you turn the gas supply back on12. If you smell gas at any point, stop: see the warning below.
  2. Power. Check the boiler's power supply first4. If there has been a power cut, the boiler should work without any intervention once electricity returns9. If it does not, check that the boiler's own switch and any fused spur are on.
  3. Pressure. Check the pressure gauge. Guidance for one water company says the gauge should be at one bar4, and the Gas Safe Register advises checking the central heating system water pressure and topping it up if it is too low, noting that boilers can lose system pressure as they age3. Our guide to boiler pressure and our steps for repressurising a combi boiler cover this in detail.
  4. Condensate pipe. In cold weather, check whether the condensate pipe has frozen11. This is one of the simple, safe checks Cadent Gas suggests for minor issues caused by freezing pipes5.

Thawing a frozen condensate pipe safely

A hot water bottle held against an outside condensate pipe
Thaw from the outlet back towards the house, using a hot water bottle rather than boiling water.

A frozen condensate pipe is the most common cold-weather cause of a lockout that a household can fix. The boiler produces acidic water as it condenses, and that water leaves through a plastic pipe. If your boiler has stopped working in the cold, check whether the condensate pipe has frozen11.

Thaw it with a hot water bottle, starting from the outlet and working back towards the house5. Do not use boiling water, and do not use a naked flame. Once the pipe is clear, the boiler should fire; if it fires up it should work normally, and if it does not, try again. If the pipe remains frozen or the boiler will not fire, call a Gas Safe registered engineer or your gas supplier14.

To stop it happening again, our guide to stopping a condensate pipe freezing covers lagging and rerouting, and frozen condensate pipes covers the signs in more detail.

When a lockout means calling a Gas Safe registered engineer

Call an engineer when the boiler locks out again after two resets, when there is no obvious cause you can check, or when the fault is clearly not related to a power cut1. If your boiler is not working but is unrelated to a power cut, you will need to contact a Gas Safe registered engineer to come out and take a look10. A gas appliance that keeps shutting itself down is telling you something is wrong inside it, and that is not a job for the reset button.

Use the Gas Safe Register to find an engineer, either at GasSafeRegister.co.uk or on 0800 408 55001. When they arrive, check their Gas Safe Register ID card15. Our guide to finding a Gas Safe registered engineer and checking their card walks through what the card should show.

SituationWhat to do
Lockout clears on the first reset and stays clearNothing further; note when it happened6
Lockout returns after two resetsCall a Gas Safe registered engineer1
Lockout follows a power cutWait for electricity to return; the boiler should recover without intervention9
Lockout in freezing weatherCheck the condensate pipe first11
Smell of gas at any pointDo not reset; call 0800 111 99912
Carbon monoxide alarm soundingLeave the property; see below16

If your boiler is serviced annually by a Gas Safe registered engineer, faults are more likely to be caught before they cause a lockout15. Our guide to boiler servicing explains what an engineer checks.

Staying warm and safe while the boiler is out

A boiler that will not fire in winter is uncomfortable rather than dangerous, provided you heat and ventilate the home sensibly. Keep warm with blankets and layered clothing, and shut the curtains and doors of unused rooms to keep the heat in18. If you use electric blankets or portable heaters, use them safely; they can be a good way to stay warm, but only if used with care19.

Check your carbon monoxide alarms while the heating is out of action. Any alarm that fails a routine test should be returned to the installer or supplier, or replaced21. Our guide to heating and cooking without mains power or gas covers the alternatives in detail.

If the boiler is out during a power cut as well, keep fridge and freezer doors closed, switch off appliances like straighteners and stoves, and keep a light on in one room so you know when power returns22. Check on vulnerable neighbours, and notify a friend or neighbour if you are anxious22. Our guide to power cuts covers the wider household steps.

Where to get help: your boiler maker, supplier and the gas emergency line

There are four routes to help, and which one you use depends on what has gone wrong.

  • Your boiler maker. For the reset procedure and fault codes specific to your model, the maker's manual is the authority. Baxi, for example, publishes its own reset instructions6.
  • A Gas Safe registered engineer. For any fault that survives two resets, or any fault unrelated to a power cut, this is the route1. Call 0800 408 5500 or use GasSafeRegister.co.uk1.
  • Your energy supplier. If you do not know how to turn off your gas, electricity or water, contact your supplier23. If your prepayment meter has run out and your supply has already stopped, your supplier has to send someone to repair or replace the meter24. Our guide to prepayment meters covers emergency credit and restarting.
  • The gas emergency line. For a smell of gas, call 0800 111 99912. Our guide to the National Gas Emergency Service explains what happens next.
A householder checking a boiler pressure gauge
The pressure gauge is the first thing to check before a reset; it should read one bar.

If you are disabled, have a health condition, or are recovering from an injury, ask your supplier about the Priority Services Register. It can give you advance notice of power cuts25, and suppliers may read your meter for you26. You will need to register again if you change suppliers or move home27. Our guide to extra support from networks and suppliers covers what else is available.

Sources (27)
  1. Boiler not working, Northern Gas Networks, 2026-10-29
  2. My boiler isn't working, SGN, 2026-10-29
  3. Boiler appliance guide, Gas Safe Register, 2026-10-29
  4. Water pressure, Yorkshire Water, 2026-10-28
  5. Winter advice, WaterSafe, 2026-10-29
  6. How to reset a Baxi boiler, Baxi, 2026-10-29
  7. Smell gas, Northern Gas Networks, 2026-10-27
  8. Carbon monoxide, Greater Manchester Fire and Rescue Service, 2026-10-29
  9. Incident hub, SGN, 2026
  10. Gas supply updates, SGN, 2026
  11. Be winter ready, SGN, 2026
  12. Gas on, Northern Gas Networks, 2026-08-24
  13. Safe home heating, Warwickshire County Council, 2026-10-29
  14. Winter safety, Wessex Water, 2026-10-28
  15. Preparing your home for winter, Royal Voluntary Service, 2026-10-29
  16. Carbon monoxide alarms, Gas Safe Register, 2026-10-29
  17. Smoke alarms and carbon monoxide detectors, Surrey County Council, 2026-08-24
  18. Loss of essential services, Greater Manchester Combined Authority, 2026-10-29
  19. Stay warm and nourished, NHS Norfolk and Suffolk ICB, 2026-10-16
  20. Carbon monoxide, North Wales Fire and Rescue Service, 2026
  21. Carbon monoxide alarms, Health and Safety Executive for Northern Ireland, 2026
  22. Power cuts, Wigan Council, 2026-10-29
  23. Preparing for a flood, Natural Resources Wales, 2026-10-29
  24. Find out if your energy meter is faulty, Citizens Advice, 2026-10-26
  25. Priority Services Register, Surrey County Council, 2026-10-29
  26. Escape routes, Cheshire Fire and Rescue Service, 2026-05-20
  27. Priority Services Register, Derbyshire County Council, 2026-10-29

Common questions

I can smell gas. Should I reset the boiler?

No. Do not press reset and do not turn any appliance back on. Open doors and windows, turn the gas emergency control valve off if you can reach it safely, and call the National Gas Emergency Service on 0800 111 999. A sulphur-like smell or a hissing sound near an appliance or meter is a gas leak warning sign, and a reset could ignite gas that has built up.

How do I top up the pressure on my boiler?

Check the pressure gauge first. Guidance for one water company puts the gauge at one bar, and the Gas Safe Register advises topping the system up if it is too low, noting that boilers can lose pressure as they age. Follow your boiler maker's own instructions for the filling loop, then switch the boiler back on and press reset if needed. If pressure keeps dropping, call a Gas Safe registered engineer.

How do I thaw a frozen condensate pipe?

If the boiler stops in cold weather, check whether the condensate pipe has frozen. Thaw it with a hot water bottle, starting from the outlet and working back towards the house. If the boiler fires up it should then work normally; if the pipe stays frozen or the boiler will not fire, call a Gas Safe registered engineer or your gas supplier.

My prepayment meter has run out. Could that be why the boiler has locked out?

It could. A boiler needs electricity and gas to run, so a meter with no credit will stop it. If your supply has already stopped, your supplier has to send someone to repair or replace the meter. If running out of credit would cause you a serious problem because you are disabled or have a health condition, you should not move to prepayment in the first place.

My carbon monoxide alarm is sounding. What do I do?

Open all doors and windows, stop using and turn off all fuel burning appliances, and leave the property, keeping doors and windows open. Do not re-enter until the alarm has stopped. Turn off the gas supply and call your nation's gas emergency helpline. If anyone feels unwell, call the emergency services.

What is the Priority Services Register and can it help me?

It is a free register run by energy suppliers and network operators for households that need extra help. It can give you advance notice of power cuts, and suppliers may read your meter for you. You may be eligible if you are recovering from an injury, among other circumstances. You need to register again if you change suppliers or move home.

My boiler locked out after a power cut. Do I need to reset it?

Usually not. When the electricity supply returns, your boiler should work without any intervention. If it does not, check the power supply, the pressure gauge and whether the condensate pipe has frozen before pressing reset. If it still will not fire, contact a Gas Safe registered engineer.